Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
1.
Eur Radiol ; 2024 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-38244046

RESUMEN

OBJECTIVE: To determine the inter-reader reliability and diagnostic performance of classification and severity scales of Neuropathy Score Reporting And Data System (NS-RADS) among readers of differing experience levels after limited teaching of the scoring system. METHODS: This is a multi-institutional, cross-sectional, retrospective study of MRI cases of proven peripheral neuropathy (PN) conditions. Thirty-two radiology readers with varying experience levels were recruited from different institutions. Each reader attended and received a structured presentation that described the NS-RADS classification system containing examples and reviewed published articles on this subject. The readers were then asked to perform NS-RADS scoring with recording of category, subcategory, and most likely diagnosis. Inter-reader agreements were evaluated by Conger's kappa and diagnostic accuracy was calculated for each reader as percent correct diagnosis. A linear mixed model was used to estimate and compare accuracy between trainees and attendings. RESULTS: Across all readers, agreement was good for NS-RADS category and moderate for subcategory. Inter-reader agreement of trainees was comparable to attendings (0.65 vs 0.65). Reader accuracy for attendings was 75% (95% CI 73%, 77%), slightly higher than for trainees (71% (69%, 72%), p = 0.0006) for nerves and comparable for muscles (attendings, 87.5% (95% CI 86.1-88.8%) and trainees, 86.6% (95% CI 85.2-87.9%), p = 0.4). NS-RADS accuracy was also higher than average accuracy for the most plausible diagnosis for attending radiologists at 67% (95% CI 63%, 71%) and for trainees at 65% (95% CI 60%, 69%) (p = 0.036). CONCLUSION: Non-expert radiologists interpreted PN conditions with good accuracy and moderate-to-good inter-reader reliability using the NS-RADS scoring system. CLINICAL RELEVANCE STATEMENT: The Neuropathy Score Reporting And Data System (NS-RADS) is an accurate and reliable MRI-based image scoring system for practical use for the diagnosis and grading of severity of peripheral neuromuscular disorders by both experienced and general radiologists. KEY POINTS: • The Neuropathy Score Reporting And Data System (NS-RADS) can be used effectively by non-expert radiologists to categorize peripheral neuropathy. • Across 32 different experience-level readers, the agreement was good for NS-RADS category and moderate for NS-RADS subcategory. • NS-RADS accuracy was higher than the average accuracy for the most plausible diagnosis for both attending radiologists and trainees (at 75%, 71% and 65%, 65%, respectively).

2.
Hand Surg Rehabil ; 42(5): 406-412, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37356568

RESUMEN

OBJECTIVES: Fractures of carpal bones other than the scaphoid are rare in children. The aim of this study was to analyze results and identify risk factors for an unfavorable outcome. MATERIAL AND METHODS: Children and adolescents up to the age of 16 years who sustained a carpal fracture other than in the scaphoid between 2004 and 2021 were reviewed in this single-center retrospective study. RESULTS: In a series of 209 children and adolescents with carpal fractures, 22 had fractures other than the scaphoid. Mean age was 13 years (range 8-16) years, with a total of 41 fractures, with highest incidences for the capitate (10), trapezium (6), triquetrum (4) and pisiform (4). Twenty-nine of these 41 fractures were missed on initial X-ray. Non-displaced fractures were treated with a short arm spica cast including the thumb. Four patients were operated on for displacement fracture or carpometacarpal subluxation. All fractures united, and patients returned to full activities. At the final consultation at a median 14 months (range 6-89) post-injury, all patients with non-displaced fractures were free of symptoms, with excellent Mayo Wrist Scores (MWS). However, three patients with operated trapezium fractures developed early radiological signs of osteoarthritis, two of them with residual pain and MWS rated only good. CONCLUSION: Non-displaced pediatric carpal fractures treated by forearm cast have excellent prognosis. Fractures of the trapezium with displacement or first carpometacarpal subluxation incur a risk of osteoarthritis despite anatomical reduction and internal fixation.


Asunto(s)
Fracturas Óseas , Traumatismos de la Mano , Luxaciones Articulares , Osteoartritis , Hueso Escafoides , Traumatismos de la Muñeca , Adolescente , Humanos , Niño , Estudios Retrospectivos , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Hueso Escafoides/diagnóstico por imagen , Hueso Escafoides/cirugía , Hueso Escafoides/lesiones , Muñeca , Traumatismos de la Muñeca/diagnóstico , Luxaciones Articulares/cirugía
3.
Ther Umsch ; 80(4): 204-208, 2023.
Artículo en Alemán | MEDLINE | ID: mdl-37122179

RESUMEN

An MRI for Every Patient with Back Pain? Abstract. Imaging in spinal disorders has changed in the past years. Improved MRI techniques allow for better image interpretation. Unchanged, however, close correlation between clinical evaluation and imaging results remains crucial for correct diagnoses and subsequent therapeutical decisions. Reimbursement cuts have made MRI more affordable in Switzerland while being widely available. This allows - if used according to guidelines - for optimal treatment of patients with spinal disorders.


Asunto(s)
Dolor de Espalda , Imagen por Resonancia Magnética , Humanos , Dolor de Espalda/diagnóstico por imagen , Suiza
4.
Ann Neurol ; 92(2): 184-194, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35599442

RESUMEN

OBJECTIVE: To examine rates of intravenous thrombolysis (IVT), mechanical thrombectomy (MT), door-to-needle (DTN) time, door-to-puncture (DTP) time, and functional outcome between patients with admission magnetic resonance imaging (MRI) versus computed tomography (CT). METHODS: An observational cohort study of consecutive patients using a target trial design within the nationwide Swiss-Stroke-Registry from January 2014 to August 2020 was carried out. Exclusion criteria included MRI contraindications, transferred patients, and unstable or frail patients. Multilevel mixed-effects logistic regression with multiple imputation was used to calculate adjusted odds ratios with 95% confidence intervals for IVT, MT, DTN, DTP, and good functional outcome (mRS 0-2) at 90 days. RESULTS: Of the 11,049 patients included (mean [SD] age, 71 [15] years; 4,811 [44%] women; 69% ischemic stroke, 16% transient ischemic attack, 8% stroke mimics, 6% intracranial hemorrhage), 3,741 (34%) received MRI and 7,308 (66%) CT. Patients undergoing MRI had lower National Institutes of Health Stroke Scale (median [interquartile range] 2 [0-6] vs 4 [1-11]), and presented later after symptom onset (150 vs 123 min, p < 0.001). Admission MRI was associated with: lower adjusted odds of IVT (aOR 0.83, 0.73-0.96), but not with MT (aOR 1.11, 0.93-1.34); longer adjusted DTN (+22 min [13-30]), but not with longer DTP times; and higher adjusted odds of favorable outcome (aOR 1.54, 1.30-1.81). INTERPRETATION: We found an association of MRI with lower rates of IVT and a significant delay in DTN, but not in DTP and rates of MT. Given the delays in workflow metrics, prospective trials are required to show that tissue-based benefits of baseline MRI compensate for the temporal benefits of CT. ANN NEUROL 2022;92:184-194.


Asunto(s)
Isquemia Encefálica , Accidente Cerebrovascular , Anciano , Isquemia Encefálica/complicaciones , Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/terapia , Femenino , Fibrinolíticos/uso terapéutico , Humanos , Imagen por Resonancia Magnética , Masculino , Estudios Prospectivos , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/terapia , Terapia Trombolítica/métodos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Flujo de Trabajo
5.
Skeletal Radiol ; 51(10): 1909-1922, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35478047

RESUMEN

A standardized guideline and scoring system should be used for the MR imaging diagnosis of peripheral neuropathy. The MR imaging-based Neuropathy Score Reporting and Data System (NS-RADS) is a newly devised classification system (in press in AJR) that can be used to communicate both type and severity of peripheral neuropathy in the light of clinical history and examination findings. The spectrum of neuropathic conditions and peripheral nerve disorders covered in this system includes nerve injury, entrapment, neoplasm, diffuse neuropathy, and post-interventional states. This classification system also describes the temporal MR imaging appearances of regional muscle denervation changes. This review article is based on the multicenter validation study pre-published in American journal of Roentgenology and discusses technical considerations of optimal MR imaging for peripheral nerve evaluation and discusses the NS-RADS classification and its severity scales with illustration of conditions that fall under each classification. The readers can gain knowledge of the NS-RADS classification system and learn to apply it in their practices for improved inter-disciplinary communications and timely patient management.


Asunto(s)
Imagen por Resonancia Magnética , Enfermedades del Sistema Nervioso Periférico , Humanos , Imagen por Resonancia Magnética/métodos , Estudios Multicéntricos como Asunto , Nervios Periféricos , Enfermedades del Sistema Nervioso Periférico/diagnóstico por imagen
6.
AJR Am J Roentgenol ; 219(2): 279-291, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35234483

RESUMEN

BACKGROUND. A standardized guideline and scoring system would improve evaluation and reporting of peripheral neuropathy (PN) on MRI. OBJECTIVE. The objective of this study was to create and validate a neuropathy classification and grading system, which we named the Neuropathy Score Reporting and Data System (NS-RADS). METHODS. This retrospective study included 100 patients with nerve imaging studies and known clinical diagnoses. Experts crafted NS-RADS using mutually agreed-on qualitative criteria for the classification and grading of PN. Different classes were created to account for the spectrum of underlying pathologies: unremarkable (U), injury (I), neoplasia (N), entrapment (E), diffuse neuropathy (D), not otherwise specified (NOS), and postintervention state (PI). Subclasses were established to describe the severity or extent of the lesions. Validation testing was performed by 11 readers from 10 institutions with experience levels ranging from 3 to 18 years after residency. After initial reader training, cases were presented to readers who were blinded to the final clinical diagnoses. Interobserver agreement was assessed using correlation coefficients and the Conger kappa, and accuracy testing was performed. RESULTS. Final clinical diagnoses included normal (n = 5), nerve injury (n = 25), entrapment (n = 15), neoplasia (n = 33), diffuse neuropathy (n = 18), and persistent neuropathy after intervention (n = 4). The miscategorization rate for NS-RADS classes was 1.8%. Final diagnoses were correctly identified by readers in 71-88% of cases. Excellent inter-reader agreement was found on the NS-RADS pathology categorization (κ = 0.96; 95% CI, 0.93-0.98) as well as muscle pathology categorization (κ = 0.76; 95% CI, 0.68-0.82). The accuracy for determining milder versus more severe categories per radiologist ranged from 88% to 97% for nerve lesions and from 86% to 94% for muscle abnormalities. CONCLUSION. The proposed NS-RADS classification is accurate and reliable across different reader experience levels and a spectrum of PN conditions. CLINICAL IMPACT. NS-RADS can be used as a standardized guideline for reporting PN and improved multidisciplinary communications.


Asunto(s)
Imagen por Resonancia Magnética , Enfermedades del Sistema Nervioso Periférico , Humanos , Imagen por Resonancia Magnética/métodos , Variaciones Dependientes del Observador , Enfermedades del Sistema Nervioso Periférico/diagnóstico por imagen , Estudios Retrospectivos
7.
Eur J Radiol ; 147: 110054, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34933213

RESUMEN

With the progress of medical oncology, it became apparent that anatomical imaging is oftentimes insufficient for therapy response evaluation. Hybrid imaging, namely 18F-FDG PET/CT has helped to overcome these limitations. The aim of this paper is to emphasize the utility and impact in clinical use of 18F-FDG PET/CT, and to give an overview of the most important 18F-FDG PET/CT tumor response criteria. We also focus on standardization of hybrid imaging techniques as this is of outmost importance to provide reliable imaging evaluation.


Asunto(s)
Fluorodesoxiglucosa F18 , Neoplasias , Humanos , Imagen Multimodal , Neoplasias/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Radiofármacos
11.
J Hand Surg Glob Online ; 2(3): 171-174, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32313878

RESUMEN

Juxta-articular myxomata are benign tumors that are mostly encountered in the vicinity of larger joints. Few cases in the hand have been reported. We present a case of a juxta-articular myxoma at the metacarpophalangeal joint of the thumb in a 40-year-old man. The preoperative diagnostic work-up included 4-dimensional magnetic resonance angiography and ultrasound. The histochemical examination of the resected tumor established the diagnosis definitively. Follow-up magnetic resonance imaging scheduled with no clinical suspicion of tumor recurrence 9 months after surgery revealed no obvious recurrence. At 14 months, the patient had full motion without pain and declined further imaging.

15.
Magn Reson Med Sci ; 18(2): 150-157, 2019 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-30416178

RESUMEN

PURPOSE: Diffusion tensor imaging (DTI) adds functional information to morphological magnetic resonance neurography (MRN) in the assessment of the brachial nerve plexus. To determine the most appropriate pulse sequence in scan times suited for diagnostic imaging in clinical routine, we compared image quality between simultaneous multi-slice readout-segmented (rs-DTI) and conventional single-shot (ss-DTI) echo-planar imaging techniques. METHODS: Institutional Review Board (IRB) approved study including 10 healthy volunteers. The supraclavicular brachial plexus, covering the nerve roots and trunks from C5 to C7, was imaged on both sides with rs-DTI and ss-DTI. Both sequences were acquired in scan times <7 min with b-values of 900 s/mm2 and with isotropic spatial resolution. RESULTS: In rs-DTI image, the overall quality was significantly better and distortion artifacts were significantly lower (P = 0.001-0.002 and P = 0.001-0.002, respectively) for both readers. In ss-DTI, a trend toward lower degree of ghosting and motion artifacts was elicited (reader 1, P = 0.121; reader 2, P = 0.264). No significant differences between the two DTI techniques were found for signal-to-noise ratios (SNR), contrast-to-noise ratios (CNR) and fractional anisotropy (FA) (P ≥ 0.475, P ≥ 0.624, and P ≥ 0.169, respectively). Interreader agreement for all examined parameters and all sequences ranged from intraclass correlation coefficient (ICC) 0.064 to 0.905 and Kappa 0.40 to 0.851. CONCLUSION: Incomparable acquisition times rs-DTI showed higher image quality and less distortion artifacts than ss-DTI. The trend toward a higher degree of ghosting and motion artifacts in rs-DTI did not deteriorate image quality to a significant degree. Thus, rs-DTI should be considered for functional MRN of the brachial plexus.


Asunto(s)
Plexo Braquial/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Imagen de Difusión Tensora , Imagen Eco-Planar , Neuroimagen/métodos , Adulto , Anisotropía , Artefactos , Plexo Braquial/patología , Medios de Contraste , Femenino , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados , Relación Señal-Ruido
16.
Invest Radiol ; 54(3): 160-168, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30418261

RESUMEN

PURPOSE: The aim of this study was to evaluate the efficiency and performance of different fat suppression techniques for clinical 7 T knee magnetic resonance imaging including the slice-selective gradient reversal (SSGR) technique. MATERIALS AND METHODS: This article is an ethical board-approved prospective study with written informed consent from 8 volunteers (mean, 31 ± 4 years). It included fat phantom and knee magnetic resonance imaging at 3 T (Magnetom Skyra; Siemens Healthcare) and at 7 T (Achieva, Philips Healthcare). At 3 T, an axial proton density-weighted turbo spin echo sequence with spectral adiabatic inversion recovery (SPAIR) was acquired. At 7 T, a series of 5 proton density-weighted turbo spin echo sequences was acquired: (a) without fat suppression, (b) with spectral presaturation with inversion recovery (SPIR), (c) with SPAIR, (d) with SSGR, and (e) with the combination of SSGR + SPIR. Additional noise scans allowed pixelwise calculation of signal-to-noise ratio and contrast-to-noise ratio maps. Quantitative data at 7 T were compared with each other but not to 3 T. Two independent radiologists evaluated overall image quality, homogeneity and grade of fat suppression, and the delineation between 2 adjacent structures. Results were compared using Wilcoxon signed rank and paired sample t tests. RESULTS: Relative signal-to-noise ratios of fat demonstrated that the SPIR technique reduced the fat signal to 45% ± 5.4%; SPAIR, 18% ± 1.2%; SSGR, 14% ± 1.1%; and SSGR + SPIR, 11% ± 0.3%. Contrast-to-noise ratio showed superior contrast between muscle-fat (P < 0.001) and fluid-fat (P ≤ 0.001) for SSGR and SSGR + SPIR. The radiologists rated the overall image quality higher at 7 T than 3 T. The homogeneity and grade of fat suppression as well as the delineation between 2 different (adjacent) structures were rated best for SSGR + SPIR. CONCLUSIONS: At 7 T, fat saturation for clinical knee imaging using SSGR and the combination of SSGR + SPIR was superior compared with standard methods based on spectrally selective radiofrequency pulses.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Articulación de la Rodilla/anatomía & histología , Imagen por Resonancia Magnética/métodos , Adulto , Femenino , Humanos , Masculino , Fantasmas de Imagen , Estudios Prospectivos , Valores de Referencia , Relación Señal-Ruido
17.
J Orthop Surg Res ; 13(1): 245, 2018 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-30285815

RESUMEN

BACKGROUND: The optimal positioning of anterior cruciate ligament graft is still controversially discussed. We therefore wanted to determine the tunnel-to-joint (TJA), tunnel-to-shaft (TSA), and graft-tunnel divergence angles which would provide the best outcome, determined by the KOOS (Knee Injury and Osteoarthritis Outcome Score). This study evaluated the clinical influence of graft orientation as measured with the KOOS questionnaire in patients with anterior cruciate ligament reconstruction with bone-patellar tendon-bone autografts. METHODS: We designed a prospective cohort study, with a 1 » year recruitment phase from March 2011 to July 2012 and a minimal follow-up period of 1 year. Inclusion criteria were patients ≥ 18 years of age receiving an ACL reconstruction with bone-patellar tendon-bone autografts at our institution after having suffered an acute ACL rupture. The primary outcome was the KOOS. Independent variables were patient age, gender, laterality of rupture, mechanism of trauma, and type of femoral and tibial fixation, as well as sagittal graft-tunnel divergence, TJA, and TSA, the latter two being assessed on coronal slices of magnetic resonance imaging. Equations modeling the relationship between TJA, TSA, and graft-tunnel divergence with the KOOS overall score were fitted, and the optimum angles were mathematically determined. RESULTS: In total, 31 patients were included in our study. Our cohort with a median age of 28 years was predominantly male. The mathematically determined optimal placement of the implant in the coronal plane was a TJA of 74.8°, a TSA of 80.1°, and a graft-tunnel divergence angle of 8.5°. CONCLUSION: With regard to patient-reported outcome, the optimal graft orientation is provided by a coronal tunnel-to-shaft angle of 80° and tunnel-to-joint angle of 75°, respectively. Interestingly, in our series, patients reported best clinical outcomes with a sagittal graft-tunnel divergence. These results should be validated in larger studies.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/métodos , Trasplante Óseo/métodos , Ligamento Rotuliano/trasplante , Medición de Resultados Informados por el Paciente , Procedimientos de Cirugía Plástica/métodos , Adulto , Estudios de Cohortes , Femenino , Fémur/cirugía , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Tibia/cirugía , Trasplante Autólogo , Adulto Joven
18.
Eur Radiol Exp ; 2(1): 7, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29708190

RESUMEN

We aimed to investigate whether different transmission settings of the dual-transmit technology may influence the amount of heat induction around an implant material dependent on its location within the magnetic field. Metallic hip implants were positioned in the magnet of a 3-T scanner at various lateral offset positions in relation to the magnetic axis in a body-phantom tank filled with polyacrylic acid gel. The temperature increase close to the implants was measured during turbo spin-echo scanning using dual-channel parallel radiofrequency (RF) transmission with circular in comparison to elliptic RF polarization. Circularly polarized transmission (CPT) induced higher temperature increases (maximum 6.2 °C) than elliptically polarized transmission (EPT) (maximum 1.5 °C). The heat induction was dependent on the distance to the isocenter with increased heating by increased distance to the isocenter. EPT showed lower heating around implants compared to the CPT as commonly used in single-transmission system; further, less heating was observed for both transmission settings closer to the magnet isocenter.

19.
Semin Musculoskelet Radiol ; 22(3): 334-343, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29791961

RESUMEN

This article provides a review of magnetic resonance neurography (MRN) and how to get started. It explains step by step how to establish MRN at an institution: how to set up MRN protocols, how to train technicians, what a report needs to contain, and how relevant findings should be communicated to the referring physician. Advanced imaging techniques such as diffusion tensor imaging are only briefly discussed at the end of the article because most of those techniques are difficult for beginners and are still not considered standard in the clinical routine.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Enfermedades del Sistema Nervioso Periférico/diagnóstico por imagen , Servicio de Radiología en Hospital/organización & administración , Radiología/educación , Protocolos Clínicos , Humanos
20.
Skeletal Radiol ; 47(9): 1269-1275, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29651713

RESUMEN

OBJECTIVE: To investigate whether upright radiographs can predict lumbar spinal canal stenosis using supine lumbar magnetic resonance imaging (MRI) and to investigate the detection performance for spondylolisthesis on upright radiographs compared with supine MRI in patients with suspected lumbar spinal canal stenosis (LSS). MATERIALS AND METHODS: In this retrospective study, conventional radiographs and MR images of 143 consecutive patients with suspected LSS (75 female, mean age 72 years) were evaluated. The presence and extent of listhesis (median ± interquartile range) were assessed on upright radiographs and supine MRI of L4/5. In addition, the grade of central spinal stenosis of the same level was evaluated on MRI according to the classification of Schizas and correlated with the severity/grading of anterolisthesis on radiographs. RESULTS: Anterolisthesis was detected in significantly more patients on radiographs (n = 54; 38%) compared with MRI (n = 28; 20%), p < 0.001. Pairwise comparison demonstrated a significantly larger extent of anterolisthesis on radiographs (9 ± 5 mm) compared with MRI (5 ± 3 mm), p < 0.001. A positive correlation was found regarding the extent of anterolisthesis measured on radiographs and the grade of stenosis on MRI (r = 0.563, p < 0.001). Applying a cutoff value of ≥5 mm anterolisthesis on radiographs results in a specificity of 90% and a positive predictive value of 78% for the detection of patients with LSS, as defined by the Schizas classification. CONCLUSION: Upright radiographs demonstrated more and larger extents of anterolisthesis compared with supine MRI. In addition, in patients with suspected LSS, the extent of anterolisthesis on radiographs (particularly ≥5 mm) is indicative of LSS and warrants lumbar spine MRI.


Asunto(s)
Vértebras Lumbares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Posicionamiento del Paciente/métodos , Radiografía/métodos , Estenosis Espinal/diagnóstico por imagen , Espondilolistesis/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Canal Medular/diagnóstico por imagen , Posición de Pie , Posición Supina , Suiza
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...